August 15, 2026 operational update
Extended the lab from host management into VMM logical networking and repeatable operations.
This working session focused on correcting host-management health, bringing the existing Hyper-V network under VMM control, and exercising APP01 through the VMM abstraction layer while preserving the isolated 10.10.20.0/24 lab behind pfSense.
09Recovered VMM host-agent health
HVHOST01 initially reported Needs Attention with VMM error 12704 even though vmms and SCVMMAgent were running and both server and agent were version 10.22.1287.0. WinRM tests passed. A VMM Run As account named HVHOST01 Management was created with the validated domain-management credential and assigned under Host Access. After refresh, host status, network, WinRM, agent service, and agent version all reported OK.
10Modeled the isolated AD network
Validated the VMM logical network ad and network site AD-10.10.20.0-24 for subnet 10.10.20.0/24. The static VMM IP pool spans 10.10.20.201 through 10.10.20.220 and VMM reports the logical network as Fully compliant.
11Resolved logical-switch conversion blockers
The existing External-LAN standard switch could not convert while the VMM logical switch used a different minimum-bandwidth mode and uplink teaming mode. The Host management port profile weight was cleared, HomeLab-Logical-Switch was changed to Absolute bandwidth mode, and its uplink mode was changed to No Uplink Team to match the single-adapter standard switch.
12Converted to a VMM logical switch
Converted External-LAN into HomeLab-Logical-Switch using the HomeLab-Uplink uplink profile. VMM completed the host-change job successfully, Hyper-V reported the new external switch name, and the host management vNIC retained 10.10.20.102/24, gateway 10.10.20.1, and DNS 10.10.20.10.
13Applied a VM traffic classification
Adjusted the built-in Medium Bandwidth Adapter profile so it was compatible with the logical switch's Absolute bandwidth mode, mapped the Medium bandwidth classification into HomeLab-Logical-Switch, and assigned that classification to APP01's virtual network adapter.
14Validated guest network and domain services
APP01 remained connected to HomeLab-Logical-Switch with status Ok. Inside the guest, 10.10.20.103/24, gateway 10.10.20.1, and DNS 10.10.20.10 remained intact. Gateway ping succeeded, DC01 resolved to 10.10.20.10, and TCP 389 to the domain controller succeeded.
15Exercised checkpoint lifecycle
Created the VMM checkpoint Pre-VMM-Lab-Changes while APP01 remained running, verified the checkpoint in APP01 properties, then deleted it and confirmed the checkpoint list returned to empty.
16Protected resource headroom
Measured HVHOST01 at four logical processors and about 8 GB RAM. APP01 Dynamic Memory was already configured with 2048 MB minimum, 4096 MB startup, and 6144 MB maximum; its active assignment had settled to 2 GB with memory status OK. No additional Windows VM was deployed so the nested host retained practical headroom.